APL/UPL DECISION TABLES
How to Order
The ordering code for APL/UPL circuit protectors may be
determined by following the steps in the decision tables shown
here.
The coding given permits a self-assigning part number; other
configurations may require a factory assigned part number.
Typical examples are units with mixed ratings, combinations of
styles or constructions not listed in the third decision table, etc.
With these, it is suggested that order entry be by description
and/or drawings and a part number will be assigned. Additionally,
it is a standard policy to establish a factory assigned part number
wherever a descriptive drawing exists to provide cross
reference, traceability and manufacturing control.
When specifying a protector for AC motor start or high inrush
applications, the peak amplitude and surge duration should be
specified for factory assistance in rating selection.
For example, the code shown is the code for a two pole UPL
protector with series trip, 20 ampere rating, 50/60Hz. short time
delay construction in all poles.
To determine the ordering number for your particular APL/UPL
unit, simply follow the steps shown. You may use this number to
place an order or as a reference for further questions you may
have.
Notes:
A The most common current values for 100% of rated current are
those listed. Please consult an Airpax office orsales representa-
tive for other values.
B All APL/UPL protectors are constructed with stainless steel
springs and plated parts. As noted in the specifications, all meet
normal requirements for moisture and salt spray resistance. If
fungus resistance is required in addition to moisture and salt
spray resistance, special procedures and markings are employed.
C Terminals will be supplied as #10-32 threaded studs up to 50
amperes. Above this amperage terminals will be ?-28 threaded
studs. All standard units will be supplied with a hex nut and two
flat washers on each threaded terminal.
D When metric threaded inserts are specified, breakers rated at
50 amperes and below will be supplied with metric threaded
terminals. For breakers rated above 50 amperes, ? -28 threaded
terminals will be supplied.
E Black handle standard.
相关PDF资料
UPL2000-D1/B BNC PLUG CRIMP STR 7538CBL 50/PK
UPL2000-D20/B BNC PLUG CRIMP STR 1505F 50/PK
UPL220-009 BNC PLUG FULL CRIMP STR 8218CBL
UPL220-013 BNC PLUG FULL CRIMP STR RG-59
UPL220-020 BNC PLUG FULL CRIMP STR 9248 CBL
UPL220-025/T50 BNC PLUG CRIMP STR AT&T734 50/PK
UPL220-025 BNC PLUG CRIMP STR AT&T 734 CBL
UPL220-026/T50 BNC PLUG CRIMP STR AT&T735 50/PK
相关代理商/技术参数
UPL111-1-60F-503 制造商:Sensata Technologies 功能描述:3 Pole
UPL111-1-61-103-B 制造商:Sensata Technologies 功能描述:Circuit Breaker Magnetic Circuit Protectors 3Pole 10A
UPL111-1-61-153 制造商:Sensata Technologies 功能描述:Circuit Breaker Magnetic Circuit Protectors 3Pole 15A
UPL111-1-61-153-B 制造商:Sensata Technologies 功能描述:Circuit Breaker Magnetic Circuit Protectors 3Pole 15A
UPL111-1-61-153-M 制造商:Sensata Technologies 功能描述:Circuit Breaker Magnetic 3Pole 15A 277VAC
UPL111-1-61-203 制造商:Sensata Technologies 功能描述:Circuit Breaker Magnetic Circuit Protectors 3Pole 20A
UPL111-1-61-203-B 制造商:Sensata Technologies 功能描述:Circuit Breaker Magnetic Circuit Protectors 3Pole 20A
UPL111-1-61-203-M 制造商:Sensata Technologies 功能描述:Circuit Breaker Magnetic 3Pole 20A 250VAC